Why the study?
Aortic valve assessment by 2D transthoracic echocardiography is complex due to the unique anatomy and dynamic nature of the left ventricular outflow tract.
Does 3D transthoracic echocardiography improve the accuracy of aortic valve assessment compared to 2D echocardiography in children?
Does 3D transthoracic echocardiography improve the accuracy of aortic valve assessment compared to 2D echocardiography in children?
3D transthoracic echocardiography provides a more accurate assessment of the aortic valve annulus and area in children compared to 2D echocardiography, correlating better with angiographic findings.
May support 3D over 2D echocardiography for aortic valve assessment in children; leaves open impact on outcomes and practice.
BACKGROUND: Aortic valve assessment by 2D transthoracic echocardiography is a relatively complex task owing to the unique anatomical features of the left ventricular outflow tract and its dynamic nature. We aimed to evaluate the accuracy of 3D transthoracic echocardiography [3D TTE] in assessing the aortic valve in children. RESULTS: The first group included 11 males and six females, with a mean age of 5.76 ± 6.39 years. All of these patients had aortic valve disease with a bicuspid variant. The second group included seven males and seven females, with a mean age of 4.4 ± 4.05 years. All of these patients had normal aortic valve morphology and had another congenital cardiac anomaly. The aortic valve annulus was assessed using the three modalities; 2D, 3D echocardiography in the vertical and horizontal diameters, and angiography. The aortic valve area was measured by 2D and 3D echocardiography using multiplane reformatted mode. The results of the analysis were then compared. They revealed that 3D echocardiographic measurement of the aortic annulus (horizontal diameter) correlated better with angiography than 2D and 3D (vertical diameter) echocardiographic measurements. There was a significant difference between the aortic valve area measured by 2D echocardiography and that measured by 3D echocardiography among the two groups, 2D echocardiography seems to underestimate the true aortic valve area. CONCLUSION: The study concluded that 3D TTE with multiplane reformatted mode allows a more accurate assessment of the aortic valve when compared to 2D echocardiography and this correlates better with the angiographic findings.
No takes yet. Share an insight, caveat, or question.
Ezzeldin et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: