Purpose: To estimate the outflow facility coefficient (C) as a function of Schlemm's canal cross-sectional area (SCAR) in healthy subjects using noninvasive oculopression tonometry (OPT). Methods: In 25 healthy volunteers, intraocular pressure (IOP) decay values were recorded by a ophthalmodynamometer, with a fixed external force (0.15 N) on the inferior-temporal eyelid, every 10 seconds, for four minutes, and again after a 30-minute rest. Schlemm's canal profile images and IOP were obtained pre-procedurally (baseline), immediately (T0), and at 1-minute intervals post-procedurally (T1, T2, T3, and T4). C was calculated for different IOPs. The SCAR, coronal, and the meridional diameter of Schlemm's canal were calculated. Results: Mean C0 for the maximum IOP was 0.020 ± 0.017 µL/min/mm Hg; mean C was 0.018 ± 0.0071 and 0.058 ± 0.0146 µL/min/mm Hg at 40 and 20 mm Hg, respectively. C was nonlinearly dependent on the IOP (R2 = 0.945). The SCAR was 5440 ± 3140.82, 3947.6 ± 2246.8, and 5375.7 ± 2662.7 µm2 at baseline, T0, and T4, respectively. The coronal diameter of SC decreased significantly from the baseline (33.02 ± 11.3 µm) to T0 (26.6 ± 9.37 µm) and recovered at T4 (32.3 ± 9.53 µm). The SCAR and IOP correlated significantly throughout (R2 = 0.9944; P < 0.001). C0 significantly correlated with the SCAR at baseline and with changes in the SCAR and IOP from T0 to T4. Conclusions: Schlemm's canal dimensions are responsible for the IOP-dependent mechanical forces, and these changes appear to directly affect outflow facility.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2020) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: