Case report demonstrates successful removal of retained sutures causing haemoptysis using endoscopic techniques, suggesting effective solutions for similar airway obstructions.
Haemoptysis can be a challenging diagnostic dilemma. The most common causes include acute respiratory infection, cancer, bronchiectasis and chronic obstructive pulmonary disease. However, in 20% of cases no clear cause can be found. We present here a rare case of a 54‐year‐old male who previously had a lobectomy for lung cancer and presented with chronic low‐grade haemoptysis caused by endobronchial polypropylene sutures. We detail their successful removal using a novel technique with flexible endobronchial scissors and flexible fibreoptic bronchoscopy under light sedation. This case highlights a rare cause of haemoptysis that can be easily missed without bronchoscopy. It also shows that flexible endoscopic scissors can be safely used in the airway with a flexible bronchoscope to remove a foreign body that is implanted in the airway, and reviews surgical techniques to prevent sutures in the airway.
No takes yet. Share an insight, caveat, or question.
Alsaeed et al. (2026) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: