Key result
Pegged glenoid components reduced the development of radiolucent lines compared to keeled components (risk difference -0.32; 95% CI -0.62, -0.03), with no difference in clinical glenoid failure.
Why the study?
Do pegged glenoid components reduce the development of radiolucent lines and glenoid failure compared to keeled components in total shoulder arthroplasty?
Systematic Review (n=203)
Do pegged glenoid components reduce the development of radiolucent lines and glenoid failure compared to keeled components in total shoulder arthroplasty?
Pegged glenoid components reduce the development of radiolucent lines compared to keeled components, but do not significantly alter clinical or radiographic failure rates.
Pegged glenoid components reduce radiolucent lines without lowering clinical failure; extends radiographic data but leaves superiority over keeled components open.
Background Limited evidence exists regarding the relative rates of glenoid loosening after total shoulder arthroplasty utilizing pegged or keeled cemented all-polyethylene glenoid components. Methods A systematic review of level I, II, and III studies comparing the development of radiolucent lines and glenoid failure after total shoulder arthroplasty with pegged or keeled glenoid components was conducted. Four articles were included in the final analysis with a total of 203 total shoulder arthroplasties comprising 107 pegged and 96 keeled glenoid components. Results Development of radiolucent lines was less likely with pegged glenoid components with a risk difference of −0.32 (95% CI −0.62, −0.03) favoring the pegged design. There was no statistically significant difference in the rate of radiographically at-risk glenoids, clinical glenoid failure, or the composite endpoint. Conclusions Although the development of radiolucent lines was less likely around pegged glenoid components, there was no significant difference in the rate of radiographic or clinical glenoid failure between pegged and keeled components. More high-quality studies are needed to determine the relative rates of glenoid loosening with pegged and keeled glenoid components.
No takes yet. Share an insight, caveat, or question.
Khazzam et al. (2017) conducted a systematic review in Total shoulder arthroplasty (n=203). Pegged glenoid components vs. Keeled glenoid components was evaluated on Development of radiolucent lines and glenoid failure (Risk difference -0.32, 95% CI -0.62, -0.03). Pegged glenoid components reduced the development of radiolucent lines compared to keeled components (risk difference -0.32; 95% CI -0.62, -0.03), with no difference in clinical glenoid failure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: