Key result
Short-term heart rate variability measurement reliability (ICC 0.67-0.95 for males, 0.69-0.97 for females) is not significantly influenced by gender or total spectral power magnitude.
Why the study?
Does gender or total spectral power magnitude influence the intra-session stability of short-term heart rate variability measurement?
Observational (n=103)
Does gender or total spectral power magnitude influence the intra-session stability of short-term heart rate variability measurement?
Short-term heart rate variability measurement reliability is robust and not significantly influenced by gender or total spectral power magnitude.
Supports short-term HRV stability irrespective of gender or spectral power; hypothesis-generating pending longitudinal validation.
Heart rate variability (HRV) has been increasingly analysed under numerous research settings. HRV measurement reliability is, however, still an unresolved issue. The main purpose is to carry out an intra-session stability evaluation of HRV parameters from short-term recordings by means of orthoclinostatic stimulation in a study group which is stratified by gender or Total Power (PT) magnitude. The goal is to make as homogeneous a study group as possible and investigate whether the reproducibility level could be influenced by these factors. The study group consisted of 103 participants (age 22.3 1.2). Standard HRV indexes were computed: PT (total spectral power), PHF (high frequency spectral power), PLF (low frequency spectral power) and LF/HF. Absolute reliability is assessed by the standard error of measurement and 95% limits of agreement; the relative reliability is assessed by the intraclass correlation coefficient. The markedly different standard error of measurement (SEM) between the Male and Female groups was not observed for any HRV parameters. The intraclass correlation coefficient (ICC) values ranged from 0.67 to 0.95 for males and from 0.69 to 0.97 for females. According to the SEM and ICC, there is no difference between the groups of High PT and Low PT. There are not any significant differences in absolute or relative reliability between the more homogeneous study groups and we have therefore concluded that HRV measurement reliability is not influenced by gender or HRV magnitude.
No takes yet. Share an insight, caveat, or question.
Cipryan et al. (2014) conducted an observational in Heart rate variability measurement reliability (n=103). Short-term heart rate variability measurement vs. Gender and Total Power magnitude strata was evaluated on Intra-session stability of HRV parameters assessed by standard error of measurement and intraclass correlation coefficient. Short-term heart rate variability measurement reliability (ICC 0.67-0.95 for males, 0.69-0.97 for females) is not significantly influenced by gender or total spectral power magnitude.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More from Journal of Human Sport and Exercise