April 1, 2018Journal of Atrial Fibrillation23 citationsOpen Access

3D Mapping for PVI- Geometry, Image Integration and Incorporation of Contact Force Into Work Flow

PSPhilipp Sommer

Structured PICO

P
Population
Patients undergoing catheter ablation for atrial fibrillation
I
Intervention
Three-dimensional mapping systems (CARTO 3 and Ensite Precision) incorporating image integration and contact force

This review highlights the workflow and technological principles of modern 3D mapping systems (CARTO 3 and Ensite Precision) for improving the precision and efficacy of pulmonary vein isolation in atrial fibrillation.

Abstract

Catheter ablation of atrial fibrillation has evolved enormously thanks to rapid improvement of modern mapping technologies, progress in catheter development and current possibilities for reduction of radiation exposure. Pulmonary vein isolation is thereby the cornerstone in this interventional treatment. Increased precision of catheter localization by modern three-dimensional mapping systems, faster and better processing of local electrograms and their immediate color-based visualization make it possible to treat even challenging arrhythmias very effectively. The commonly used three-dimensional mapping systems CARTO 3 (Biosense Webster, Irvine, Ca.) and Ensite Precision (St. Jude Medical, St. Paul, Min) differ in construction and principles of the underlying mapping technology. In this review article, we aim to emphasize the most important aspects of possibilities that make both systems so valuable for interventional treatment of atrial fibrillation. We present a modern workflow, that unites three-dimensional LA mapping with collecting relevant local information, image integration for refining the map and beneficial use of contact force based ablation approach.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Philipp Sommer (2018) studied this question.

synapsesocial.com/papers/6a1bce581567d2fc4d5f0a9bhttps://doi.org/10.4022/jafib.1795
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Impact of Image Integration on Catheter Ablation for Atrial Fibrillation Using Three‐Dimensional Electroanatomic Mapping: A Meta‐Analysis2012 · 19 citations
  2. 2Nonfluoroscopic Catheter Visualization in Atrial Fibrillation Ablation2014 · 51 citations
  3. 31362Prospective use of ablation index targets improves clinical outcomes following ablation for atrial fibrillation2017 · 47 citations
  4. 4Area Under the Real‐Time Contact Force Curve (Force–Time Integral) Predicts Radiofrequency Lesion Size in an In Vitro Contractile Model2010 · 264 citations
  5. 5Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation2017 · 160 citations