Validation study reveals superior early fault detection using a modified cumulative sum method in wind turbines, suggesting improved prevention of gearbox and generator breakdowns.
Unexpected failures in engineering systems lead to expensive maintenance actions and should be avoided if at all possible. This is particularly true for wind turbine systems for which unexpected failures not only demand costly repairs but also cause long downtime. Motivated by this need, we present an accumulation method for fault early warning and failure anticipation. Our research shows that one critical element allowing the ability of early warning is to accumulate the small-magnitude symptoms resulting from gradual changes in an engineering system like wind turbines. Our idea is inspired by the classical cumulative sum method, or CUSUM, but we have to redesign the accumulation mechanism for tackling unique challenges in wind turbine data. The new accumulation method is applied to two real wind turbine datasets, one with gearbox failures and the other with generator failures, and demonstrates superior performance as compared with CUSUM.