With 2 µm pumping, a 4 µm InAsSb/GaSb double heterostructure laser operated at 86.5 K yielded 11% slope power efficiency and 16 mW CW power. Pulsed operation up to 211 K was observed. The threshold and efficiency were studied as functions of temperature and pump wavelength.
No takes yet. Share an insight, caveat, or question.
Le et al. (1994) studied this question.