Computed tomography (CT) serves as a noninvasive technique for pinpointing specific areas within objects, facilitating the examination of soil distributions and localized flow processes within soil pore networks. CT scanning yields cross-sectional sequences that unveil insights into the internal structure of pore networks, which is crucial for understanding root–soil interactions. In this investigation, we explore the potential of employing a high-resolution amorphous selenium (a-Se) direct conversion detector coupled with complementary metal–oxide–semiconductor (CMOS) readouts for micro-CT scanning of soil matrices. This approach aims to visualize the aggregation status and pore network connectivity within intact soil. In addition, we compare the capabilities of the a-Se/CMOS detector with other commercially available detectors evaluating performance in terms of spatial resolution, noise levels, and overall imaging quality. The integration of a-Se’s intrinsic high spatial resolution with small-pixel CMOS readouts enables detailed visualization of soil aggregates in plant samples. By varying X-ray energy and soil thickness, we achieved a spatial resolution of <tex-math notation="LaTeX">≤</tex-math> 25 <tex-math notation="LaTeX">μ</tex-math>m and a noise-limited performance of eight photons/pixel at 20 keV. Although thick soil presents challenges due to high X-ray attenuation, finer details are discernible in thinner samples, underscoring the importance of careful selection of soil thickness and container material.
No takes yet. Share an insight, caveat, or question.
Fiallo et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: