Key result
Impella 2.5 reduces LV volumes and external work more than IABP in simulated cardiogenic shock.
Why the study?
Cardiogenic shock causes acute left ventricular failure, and the study aimed to compare the hemodynamic and energetic effects of Impella and IABP using a software simulator.
Does Impella 2.5 improve hemodynamic and energetic variables compared to IABP in a simulated model of cardiogenic shock?
Does Impella 2.5 improve hemodynamic and energetic variables compared to IABP in a simulated model of cardiogenic shock?
In an in silico simulation of cardiogenic shock, Impella 2.5 provided greater reductions in left ventricular volumes and external work compared to IABP.
Greater simulated LV unloading with Impella 2.5 vs IABP warrants clinical caution; leaves open translation to human cardiogenic shock outcomes.
Cardiogenic shock (CS) is part of a clinical syndrome consisting of acute left ventricular failure causing severe hypotension leading to inadequate organ and tissue perfusion. The most com-monly used devices to support patients affected by CS are Intra-Aortic Balloon Pump (IABP), Impella 2.5 pump and Extracorporeal Membrane Oxygenation. The aim of this study is the com-parison between Impella and IABP using CARDIOSIM© software simulator of the cardiovascular system. The results of the simulations included baseline conditions from a virtual patient in CS followed by IABP assistance in synchronized mode with different driving and vacuum pressures. Subsequently, the same baseline conditions were supported by the Impella 2.5 with different ro-tational speeds. The percentage variation with respect to baseline conditions was calculated for hemodynamic and energetic variables during IABP and Impella assistance. Impella pump driven with a rotational speed of 50000 rpm increased the total flow by 4.36% with a reduction in left ventricular end diastolic volume (LVEDV) by ≅15% to ≅30%. A reduction in left ventricular end systolic volume (LVESV) by ≅10% to ≅18% (≅12% to ≅33%) was observed with IABP (Impella) as-sistance. Taking into account the limitations of a simulation setting, this study highlights that assistance with the Impella device leads to higher reduction in LVESV, LVEDV, left ventricular external work and left atrial pressure-volume loop area compared to IABP support.
No takes yet. Share an insight, caveat, or question.
Lazzari et al. (2023) studied Cardiogenic shock (n=1). Impella 2.5 vs. Intra-Aortic Balloon Pump (IABP) was evaluated on Percentage variation in left ventricular end systolic volume (LVESV) and left ventricular end diastolic volume (LVEDV). In a simulated model of cardiogenic shock, Impella 2.5 provided greater reduction in left ventricular volumes and external work compared to IABP support.