Key result
Hot balloon ablation and cryoballoon ablation for persistent atrial fibrillation demonstrated comparable arrhythmia recurrence rates at 18 months (11% vs. 18%; p=0.26) and safety profiles.
Why the study?
The clinical efficacy and safety of hot balloon ablation for the treatment of persistent AF remained unclear.
Does hot balloon ablation improve electrically isolated surface area and reduce arrhythmia recurrence compared to cryoballoon ablation in patients with persistent atrial fibrillation?
Cohort (n=158)
Does hot balloon ablation improve electrically isolated surface area and reduce arrhythmia recurrence compared to cryoballoon ablation in patients with persistent atrial fibrillation?
Hot balloon ablation and cryoballoon ablation demonstrate comparable clinical efficacy and safety for persistent atrial fibrillation, despite hot balloon ablation creating a significantly larger isolated surface area.
Answers are grounded in this paper and cite their sources.
Comparable efficacy and safety support either modality in persistent AF; leaves open whether larger isolation area improves outcomes.
INTRODUCTION: The clinical efficacy and safety of hot balloon ablation (HBA) for the treatment of persistent AF (PerAF) remain unclear. We aimed to evaluate the clinical efficacy and safety of HBA versus cryoballoon ablation (CBA) as a treatment for PerAF. METHODS: Of 195 consecutive patients who underwent initial catheter ablation for PerAF (AF lasting for longer than 7 days but shorter than 12 months), 158 propensity score-matched (79 HBA and 79 CBA) patients were included in our retrospective study. All patients who underwent HBA received applications of energy to the upper posterior LA wall with a larger balloon in addition to single shots to each pulmonary vein (PV) ostium, whereas those who underwent CBA received simple single-shot applications. The electrically isolated surface area (ISA), including the PV antrum and part of the posterior LA wall, was assessed by high-resolution mapping. RESULTS: The success of the PV isolation with balloon shots alone did not differ between HBA and CBA (81% vs. 85%; p = .52). The ISA was generally wide in both groups and significantly larger in the HBA group than in the CBA group (61 ± 16% vs. 51 ± 12%; p < .001). The incidence of procedure-related complications did not differ significantly (HBA 4% vs. CBA 1%; p = .62) nor did the arrhythmia recurrence rate (HBA 11% vs. CBA 18% at 18 months; p = .26). CONCLUSION: Despite the difference in protocols, HBA and CBA performed for PerAF appear comparable in terms of wide antral lesion creation, clinical efficacy, and safety. Further prospective studies, based on a unified methodology, are needed.
No takes yet. Share an insight, caveat, or question.
Wakamatsu et al. (2020) conducted a cohort in Persistent atrial fibrillation (n=158). Hot balloon ablation vs. Cryoballoon ablation was evaluated on Arrhythmia recurrence rate (p=.26). Hot balloon ablation and cryoballoon ablation for persistent atrial fibrillation demonstrated comparable arrhythmia recurrence rates at 18 months (11% vs. 18%; p=0.26) and safety profiles.