The electromotive force (EMF) observer-based sensorless algorithms are sensitive to temperature rise because it requires the stator resistance (R s ) or the rotor flux linkage (ψ r ). The temperature measuring of an operating motor can be difficult, therefore, adaptive sensorless algorithms with online R s and ψ r estimation are appreciated. However, existing methods require extra signal injections, transient operations or estimate R s and ψ r one at a time to overcome the rank-deficient problem. In this paper, an adaptive EMF observer which is able to estimate both R s and ψ r simultaneously without requiring any signal injections or transient operations is proposed. The method exploits the harmonic back EMFs (HBEMF) to serve as a novel reference model and regulates the R s value in the EMF observer accordingly. The rank deficient problem is solved with the extra information provided by the HBEMFs. To make use of the HBEMFs, a parameter insensitive extraction method and an algorithm to calculate the rotor position from them are proposed. With the proposed reference model, an adaptive scheme to regulate R s is proposed. To obtain the rotor flux linkage, a ψ r estimator is also developed. The effectiveness of these proposed methods is verified with experiments and simulations.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2018) studied this question.
Synapse has enriched 4 closely related papers on similar clinical questions. Consider them for comparative context: