Key result
A novel nanoflow liquid chromatography-parallel reaction monitoring mass spectrometry method successfully quantified angiotensin peptides in HUVEC cultures with a limit of detection of 0.1-0.5 pg.
Why the study?
The study aimed to develop an analytical LC-MS/MS method to quantify multiple angiotensin peptides in human umbilical vein endothelial cell culture supernatant.
The developed nanoflow LC-MS/MS method provides a highly sensitive and precise approach for simultaneously quantifying multiple angiotensin peptides in HUVEC culture supernatants.
May advance in vitro renin-angiotensin research; leaves open translation to clinical samples or in vivo models.
BACKGROUND: This study aimed to develop an analytical method using liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of angiotensin (Ang) I, Ang (1-9), Ang II, Ang (1-7), Ang (1-5), Ang III, Ang IV in human umbilical vein endothelial cell (HUVEC) culture supernatant. METHODS: HUVEC culture supernatant was added with gradient concentrations (0.05-1,000 ng/ml) of standard solutions of the Ang peptides. These samples underwent C18 solid-phase extraction and separation using a preconcentration nano-liquid chromatography mass spectrometry system. The target peptides were detected by a Q Exactive quadrupole orbitrap high-resolution mass spectrometer in the parallel reaction monitoring mode. Ang converting enzyme (ACE) in HUVECs was silenced to examine Ang I metabolism. RESULTS: The limit of detection was 0.1 pg for Ang II and Ang III, and 0.5 pg for Ang (1-9), Ang (1-7), and Ang (1-5). The linear detection range was 0.1-2,000 pg (0.05-1,000 ng/ml) for Ang II and Ang III, and 0.5-2,000 pg (0.25-1,000 ng/ml) for Ang (1-9) and Ang (1-5). Intra-day and inter-day precisions (relative standard deviation) were <10%. Ang II, Ang III, Ang IV, and Ang (1-5) were positively correlated with ACE expression by HUVECs, while Ang I, Ang (1-7), and Ang (1-9) were negatively correlated. CONCLUSION: The nanoflow liquid chromatography-parallel reaction monitoring mass spectrometry-based methodology established in this study can evaluate the Ang peptides simultaneously in HUVEC culture supernatant.
No takes yet. Share an insight, caveat, or question.
He et al. (2020) studied Angiotensin peptide quantification. Nanoflow liquid chromatography-parallel reaction monitoring mass spectrometry was evaluated on Limit of detection and linear detection range for Angiotensin peptides. A novel nanoflow liquid chromatography-parallel reaction monitoring mass spectrometry method successfully quantified angiotensin peptides in HUVEC cultures with a limit of detection of 0.1-0.5 pg.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: