Key result
Temporary ASD balloon occlusion in patients with baseline LVEDP ≥15 mmHg caused significantly greater increases in LVEDP (9 vs 2 mmHg, p=0.03) than in those with baseline LVEDP <15 mmHg.
Why the study?
ASD closure in patients with LV diastolic dysfunction may precipitate LV failure, and data regarding temporary ASD occlusion in this scenario are limited.
Does baseline LVEDP predict changes in LAP/PAWP during temporary ASD balloon occlusion in adults with suspected LV diastolic dysfunction?
Observational (n=27)
Does baseline LVEDP predict changes in LAP/PAWP during temporary ASD balloon occlusion in adults with suspected LV diastolic dysfunction?
Absolute Event Rate: 9% vs 2%
p-value: p=0.03
Baseline LVEDP ≥15 mmHg strongly predicts significant increases in left atrial pressure during temporary ASD balloon occlusion, helping identify patients at risk for LV failure post-closure.
Baseline LVEDP ≥15 mmHg was associated with greater LVEDP rise during ASD occlusion; leaves open prospective validation for post-closure risk stratification.
OBJECTIVE: To review our experience with balloon testing prior to atrial septal defect (ASD) closure in adults with left ventricular (LV) diastolic dysfunction. BACKGROUND: ASD closure in patients with LV diastolic dysfunction may precipitate LV failure. Temporary ASD occlusion has been used in this scenario but data are limited. METHODS: Retrospective review of 27 patients age ≥ 50 years undergoing temporary ASD balloon occlusion between 2000 and 2018 for suspected LV diastolic dysfunction or elevated LV end-diastolic pressure (LVEDP). RESULTS: Median age was 72 years (IQR 66.7; 75.2). Atrial fibrillation was seen in 58% of patients, hypertension in 58%, and coronary artery disease in 26%; 52% were females. Median ASD size was 13 mm (10; 18) and Qp/Qs 1.8 (1.6; 2.2). Median LVEDP was 14 mmHg (12; 22); pulmonary artery wedge pressure (PAWP) 12 mmHg (9; 16.5) and left atrial pressure (LAP) 13.5 mmHg (8; 16.3). After a median of 5 min (3; 10) of balloon occlusion, patients with baseline LVEDP ≥15 mmHg had more significant increases in LVEDP (9 [6; 12] vs. 2 mmHg [0.5; 5]; p = 0.03) and LAP/PAWP (10.5 [8.3; 16.3] vs. 1.5 mmHg [-1.5; 3]; p = 0.0003) than those with baseline LVEDP <15 mmHg. None of those with a baseline LVEDP <15 mmHg had a LAP/PAWP >15 mmHg during balloon testing compared to 92% of patients with a baseline LVEDP ≥15 mmHg. CONCLUSION: LVEDP might be used to predict LAP post-ASD closure. Comorbidities typically associated with LV diastolic dysfunction are common in these patients and should be considered in their management.
No takes yet. Share an insight, caveat, or question.
Miranda et al. (2019) conducted an observational in Atrial septal defect with suspected left ventricular diastolic dysfunction (n=27). Temporary ASD balloon occlusion vs. Baseline LVEDP <15 mmHg was evaluated on Increase in LVEDP during balloon occlusion (p=0.03). Temporary ASD balloon occlusion in patients with baseline LVEDP ≥15 mmHg caused significantly greater increases in LVEDP (9 vs 2 mmHg, p=0.03) than in those with baseline LVEDP <15 mmHg.