Key points are not available for this paper at this time.
Characterizes dynamic VERP in canine models; leaves open translation to human pacing protocols.
After an abrupt decrease in pacing cycle length (PCL), the ventricular effective refractory period (VERP) shortens. The pacing protocol needed to determine accurate and reproducible values for the VERP during this process is elaborate and time consuming. In this study, steady-state values of VERP at 800 and 350 msec PCL and dynamic values of VERP due to an abrupt change in PCL from 800 to 350 msec were determined. This was done for 11 different dogs to test the interindividual variation and repetitively in the same dog to test the intraindividual variation. The results for steady-state and dynamic values of the VERP show a wide range for both groups. This means that accurate prediction of steady-state and dynamic values of VERP based on previous measurements is not possible.
No takes yet. Share an insight, caveat, or question.
LEERSSEN et al. (1994) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: