Why the study?
The authors aimed to assess a new tool to identify the slow pathway by activation mapping using CARTO PRIME V7.
Does slow pathway radiofrequency catheter ablation guided by CARTO 3 V7 automatic activation mapping prevent AVNRT recurrences safely in patients undergoing ablation for AVNRT?
Does slow pathway radiofrequency catheter ablation guided by CARTO 3 V7 automatic activation mapping prevent AVNRT recurrences safely in patients undergoing ablation for AVNRT?
Automatic activation mapping using the CARTO 3 V7 system is a safe and effective approach for guiding slow pathway ablation in AVNRT, resulting in zero recurrences and low fluoroscopy exposure.
Supports feasibility of CARTO 3 V7-guided AVNRT ablation; hypothesis-generating and requires randomized confirmation before practice change.
Background Slow pathway (SP) ablation is the cornerstone for atrioventricular nodal reentry tachycardia (AVNRT) treatment, and a low-voltage bridge offers a good target during mapping using low x-ray exposure. We aimed to assess a new tool to identify SP by activation mapping using the last CARTO3® version, i.e., CARTO PRIME® V7 (Biosense Webster, Diamond Bar, CA, USA) Methods and results Right atrial septum and triangle of Koch 3D-activation map were obtained from intracardiac contact mapping during low x-ray CARTO 3® procedure. In 60 patients (mean age 60.3 ± 14.7, 61% females) undergoing ablation for AVNRT, an automatic activation map using a DECANAV® mapping catheter and CARTO® Confidense™, Coherent, and FAM DX software modules were obtained. The SP was identified in all patients as the latest atrioventricular node activation area; RF catheter ablation (RFCA) in that region elicited junctional beats. The mean procedural time was 150.3 ± 48.3 min, the mean fluoroscopy time exposure was 2.9 ± 2 min, the mean dose-area product (DAP) was 16.5 ± 2.7 cGy/cm 2 . The mean number of RF applications was 3.9 ± 2, the mean ablation index was 428.6 ± 96.6, and the mean contact force was 8 ± 2.8 g. There were no adverse event during the procedure, and no AVNRT recurrences occurred during a mean follow-up of 14.3 ± 8.3 months. Conclusion Ablation of the SP by automatic mapping using Confidense™, Coherent, and FAM DX software modules is an innovative, safe, and effective approach to AVNRT ablation. The CARTO3® V7 system shows on a 3D map the latest AV node activation area during sinus rhythm allowing low fluoroscopy time and highly effective RFCA.
No takes yet. Share an insight, caveat, or question.
Chieffo et al. (2023) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: