A comb filter based signal processing method effectively reduced motion artifacts from photoplethysmographic signals and significantly improved the accuracy of blood oxygen saturation calculations.
Why the study?
Does a comb filter based signal processing method improve the quality of PPG signals and accuracy of SpO2 by reducing motion artifacts?
Does a comb filter based signal processing method improve the quality of PPG signals and accuracy of SpO2 by reducing motion artifacts?
A comb filter based signal processing method effectively reduces motion artifacts in PPG signals, significantly improving the accuracy of derived SpO2 measurements.
A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the present study we present a comb filter based signal processing method. Firstly, wavelet de-noising was implemented to preliminarily suppress a part of the MAs. Then, the PPG signal in the time domain was transformed into the frequency domain by a fast Fourier transform (FFT). Thirdly, the PPG signal period was estimated from the frequency domain by tracking the fundamental frequency peak of the PPG signal. Lastly, the MAs were removed by the comb filter which was designed based on the obtained PPG signal period. Experiments with synthetic and real-world datasets were implemented to validate the performance of the method. Results show that the proposed method can effectively restore the PPG signals from the MA corrupted signals. Also, the accuracy of blood oxygen saturation (SpO2), calculated from red and infrared PPG signals, was significantly improved after the MA reduction by the proposed method. Our study demonstrates that the comb filter can effectively reduce the MAs from a PPG signal provided that the PPG signal period is obtained.
No takes yet. Share an insight, caveat, or question.
Peng et al. (2015) studied Motion artifacts in photoplethysmographic (PPG) signals. Comb filter based signal processing method vs. Unprocessed MA corrupted signals was evaluated on Reduction of motion artifacts and accuracy of blood oxygen saturation (SpO2). A comb filter based signal processing method effectively reduced motion artifacts from photoplethysmographic signals and significantly improved the accuracy of blood oxygen saturation calculations.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: