Key result
Automated phase-contrast cardiovascular magnetic resonance flow-rate parameters accurately detected left ventricular diastolic dysfunction with a sensitivity >0.83, specificity >0.91, and accuracy >0.89.
Why the study?
Does automated evaluation of phase-contrast cardiovascular magnetic resonance data accurately assess left ventricular diastolic function compared to Doppler echocardiography in patients with severe aortic valve stenosis?
Cross-Sectional (n=53)
No
Does automated evaluation of phase-contrast cardiovascular magnetic resonance data accurately assess left ventricular diastolic function compared to Doppler echocardiography in patients with severe aortic valve stenosis?
Automated extraction of diastolic parameters from PC-CMR is reproducible, correlates well with echocardiography, and accurately detects LV diastolic dysfunction.
May support automated PC-CMR for LV diastolic assessment in severe AS; leaves open prospective outcome validation.
BACKGROUND: Early detection of diastolic dysfunction is crucial for patients with incipient heart failure. Although this evaluation could be performed from phase-contrast (PC) cardiovascular magnetic resonance (CMR) data, its usefulness in clinical routine is not yet established, mainly because the interpretation of such data remains mostly based on manual post-processing. Accordingly, our goal was to develop a robust process to automatically estimate velocity and flow rate-related diastolic parameters from PC-CMR data and to test the consistency of these parameters against echocardiography as well as their ability to characterize left ventricular (LV) diastolic dysfunction. RESULTS: We studied 35 controls and 18 patients with severe aortic valve stenosis and preserved LV ejection fraction who had PC-CMR and Doppler echocardiography exams on the same day. PC-CMR mitral flow and myocardial velocity data were analyzed using custom software for semi-automated extraction of diastolic parameters. Inter-operator reproducibility of flow pattern segmentation and functional parameters was assessed on a sub-group of 30 subjects. The mean percentage of overlap between the transmitral flow segmentations performed by two independent operators was 99.7 ± 1.6%, resulting in a small variability (<1.96 ± 2.95%) in functional parameter measurement. For maximal myocardial longitudinal velocities, the inter-operator variability was 4.25 ± 5.89%. The MR diastolic parameters varied significantly in patients as opposed to controls (p < 0.0002). Both velocity and flow rate diastolic parameters were consistent with echocardiographic values (r > 0.71) and receiver operating characteristic (ROC) analysis revealed their ability to separate patients from controls, with sensitivity > 0.80, specificity > 0.80 and accuracy > 0.85. Slight superiority in terms of correlation with echocardiography (r = 0.81) and accuracy to detect LV abnormalities (sensitivity > 0.83, specificity > 0.91 and accuracy > 0.89) was found for the PC-CMR flow-rate related parameters. CONCLUSIONS: A fast and reproducible technique for flow and myocardial PC-CMR data analysis was successfully used on controls and patients to extract consistent velocity-related diastolic parameters, as well as flow rate-related parameters. This technique provides a valuable addition to established CMR tools in the evaluation and the management of patients with diastolic dysfunction.
No takes yet. Share an insight, caveat, or question.
Bollache et al. (2010) conducted a cross-sectional in Severe aortic valve stenosis with preserved LV ejection fraction (n=53). Automated phase-contrast cardiovascular magnetic resonance (PC-CMR) vs. Doppler echocardiography was evaluated on EfMR/AfMR ratio (flow rate-related parameter) (p=<0.0001). Automated phase-contrast cardiovascular magnetic resonance flow-rate parameters accurately detected left ventricular diastolic dysfunction with a sensitivity >0.83, specificity >0.91, and accuracy >0.89.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: