Answers are grounded in this paper and cite their sources.
A method for stereotactic high-dose radiotherapy of malignancies in the abdomen has been developed. A stereotactic frame for the body has been developed and a method for fixation of the patient in the frame is described. The reproducibility in the stereotactic system of tumours in the liver and the lung was found to be within 5-8 mm for 90% of the patient set-ups. The diaphragmatic movements were reduced to 5-10 mm, by applying a pressure on the abdomen. An analytical method is used to calculate dose distributions for a continuum of beams in an isocentric treatment technique. The advantage of a heterogeneous target dose is demonstrated and proposed for the present application. A non-coplanar treatment technique, using eight individually shaped beams is proposed and has been used for patient treatments. The dose distribution for a patient with a metastasis in the liver is shown as well as dose volume histograms for the target and the liver.
No takes yet. Share an insight, caveat, or question.
Lax et al. (1994) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: