High-precision interpolation of LISA phase measurements allows signal reconstruction and formulation of time-delay interferometry (TDI) combinations to be conducted in postprocessing. The reconstruction is based on phase measurements made at approximately 10 Hz (for a 1 Hz signal bandwidth) at regular intervals independent of the TDI delay times. Interpolation introduces an error less than 1×10^-8 with continuous data segments as short as 2 s in duration. The 10 Hz sampling rate represents an increase from the 2 Hz sampling rate needed for the original implementation of TDI. The advantages of this technique include increased flexibility of the data analysis and significantly simplified hardware.
No takes yet. Share an insight, caveat, or question.
Shaddock et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: