New voltage-sensitive ElectroFluor (EF) dyes that emit across the visible and near-infrared spectrum (e.g., 730 nm) were recently developed. We evaluated EF-530, EF-630, and EF-730p-dyes spectrally orthogonal to green fluorescent protein (GFP)-at excitation wavelengths outside the conventional 470 nm range used for GFP-based indicators. Although previously applied in cardiac voltage imaging, their performance in neuronal tissue remains untested. We performed side-by-side comparisons using population voltage imaging in mouse cerebral cortex slices at optimal excitation wavelengths (530, 630, and 730 nm) and assessed cross-channel signal bleed-through across four excitation wavelengths (475, 530, 630, and 730 nm). All dyes produced robust optical signals at their optimal wavelengths, though non-preferred channels exhibited bleed-through with distinct amplitudes, polarities, and photobleaching patterns. These results provide detailed quantifications of EF dye performance for neuronal population imaging.
No takes yet. Share an insight, caveat, or question.
Antic et al. (2025) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: