PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
June 23, 2010IEEE Transactions on Medical Imaging328 citations

Intensity-Based Image Registration by Minimizing Residual Complexity

View Full Paper
AMAndriy MyronenkoXSXubo Song

Key Points

  • This research aims to develop a new similarity measure for image registration that addresses limitations in existing methods.
  • Proposed a novel similarity measure that considers intensity nonstationarities and spatially varying distortions.
  • Derived the measure by analytically solving for the intensity correction field and its adaptive regularization.
  • Evaluated performance on both artificial and real-world image registration problems.
  • The new similarity measure produced accurate registration results across test scenarios.
  • Outperformed state-of-the-art similarity measures in handling complex intensity distortions.

Abstract

Accurate definition of the similarity measure is a key component in image registration. Most commonly used intensity-based similarity measures rely on the assumptions of independence and stationarity of the intensities from pixel to pixel. Such measures cannot capture the complex interactions among the pixel intensities, and often result in less satisfactory registration performances, especially in the presence of spatially-varying intensity distortions. We propose a novel similarity measure that accounts for intensity nonstationarities and complex spatially-varying intensity distortions in mono-modal settings. We derive the similarity measure by analytically solving for the intensity correction field and its adaptive regularization. The final measure can be interpreted as one that favors a registration with minimum compression complexity of the residual image between the two registered images. One of the key advantages of the new similarity measure is its simplicity in terms of both computational complexity and implementation. This measure produces accurate registration results on both artificial and real-world problems that we have tested, and outperforms other state-of-the-art similarity measures in these cases.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Myronenko et al. (2010) studied this question.

synapsesocial.com/papers/6a1e844e8a8a69122355fabahttps://doi.org/10.1109/tmi.2010.2053043
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Multiscale Approach for Variational Problem Joint Diffeomorphic Image Registration and Intensity Correction: Theory and Application2024
  2. 2Novel feature-based method for multi-modal biomedical image registration compared to intensity-based technique2025
  3. 3Three-Stage Approach for 2D/3D Diffeomorphic Multimodality Image Registration with Textural Control2024 · 5 citations
  4. 4An Effective Non-Rigid Registration Approach for Ultrasound Images Based on the Improved Variational Model of Intensity, Local Phase Information and Descriptor Matching2026
  5. 5Diffeomorphic image registration with bijective consistency2024 · 2 citations