The adaptive sliding-mode control of a high efficiency non-isolated buck-boost converter based on Zeta converter is presented. The converter has a dc gain higher than that of the Zeta converter and is a sixth-order system. The controller uses the inductor current error and a proportional term to generate the control action. The reference inductor current is first calculated using the estimated load conductance obtained from an adaptation algorithm. The proposed and existing sliding-mode controllers are closely related under certain conditions. The stability analysis of the closed-loop system is performed and sheds light on the controller’s effectiveness. Experimental results are given to validate the theory.
No takes yet. Share an insight, caveat, or question.
Chok-You Chan (2021) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: