Key result
The maze procedure using only a bipolar radiofrequency device restored sinus rhythm in 71.4% of patients compared to 39.3% with standard ablation (p=0.002) at first postdischarge follow-up.
Why the study?
Does the maze procedure using only a bipolar radiofrequency device improve sinus rhythm restoration compared to standard radiofrequency ablation in patients with atrial fibrillation?
Cohort (n=91)
No
Does the maze procedure using only a bipolar radiofrequency device improve sinus rhythm restoration compared to standard radiofrequency ablation in patients with atrial fibrillation?
Performing the maze procedure using only a bipolar radiofrequency device is safe and achieves higher rates of sinus rhythm restoration compared to standard bipolar/unipolar ablation.
Bipolar-only maze associated with higher sinus rhythm rates; hypothesis-generating pending randomized confirmation.
Purpose: Although the maze procedure using a radiofrequency ablation device is a prevalent treatment for atrial fibrillation, a bipolar radiofrequency device is generally not used on the mitral and tricuspid annulus owing to the risk of coronary artery injury. We report the performance of the maze procedure using only a bipolar radiofrequency ablation device in our institute since 2009. Methods: We performed the maze procedure using only a bipolar device in 35 patients (bipolar group) and compared their operative outcomes with 56 patients who underwent standard radiofrequency ablation using bipolar and unipolar devices (standard group) for atrial fibrillation. Results: Preoperative characteristics were similar in the two groups. Operative data were also similar in the two groups except for a higher number of concomitant tricuspid valve repairs in the bipolar group (p = 0.007). There were no significant differences in mortality and morbidity between the two groups. Sinus rhythm was restored in a significantly higher number of patients in the bipolar group (71.4%) than in the standard group (39.3%; p = 0.002) at the first postdischarge follow-up. Conclusion: The maze procedure using only a bipolar radiofrequency device can be safely performed and results in a satisfactory sinus rhythm restoration.
No takes yet. Share an insight, caveat, or question.
Kawasaki et al. (2016) conducted a cohort in Atrial fibrillation (n=91). Maze procedure using only a bipolar radiofrequency ablation device vs. Standard radiofrequency ablation using bipolar and unipolar devices was evaluated on Sinus rhythm restoration at the first postdischarge follow-up (p=0.002). The maze procedure using only a bipolar radiofrequency device restored sinus rhythm in 71.4% of patients compared to 39.3% with standard ablation (p=0.002) at first postdischarge follow-up.