PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
March 10, 2014Journal of Applied Physics31 citations

Intracellular performance of tailored nanoparticle tracers in magnetic particle imaging

View Full Paper
HAHamed AramiKKKannan M. Krishnan

Key Points

Key points are not available for this paper at this time.

Abstract

Magnetic Particle Imaging (MPI) is a quantitative mass-sensitive, tracer-based imaging technique, with potential applications in various cellular imaging applications. The spatial resolution of MPI, in the first approximation, improves by decreasing the full width at half maximum (FWHM) of the field-derivative of the magnetization, dm/dH of the nanoparticle (NP) tracers. The FWHM of dm/dH depends critically on NPs’ size, size distribution, and their environment. However, there is limited information on the MPI performance of the NPs after their internalization into cells. In this work, 30 to 150 μg of the iron oxide NPs were incubated in a lysosome-like acidic buffer (0.2 ml, 20 mM citric acid, pH 4.7) and investigated by vibrating sample magnetometry, magnetic particle spectroscopy, transmission electron microscopy, and dynamic light scattering (DLS). The FWHM of the dm/dH curves of the NPs increased with incubation time and buffer to NPs ratio, consistent with a decrease in the median core size of the NPs from ∼20.1 ± 0.98 to ∼18.5 ± 3.15 nm. Further, these smaller degraded NPs formed aggregates that responded to the applied field by hysteretic reversal at higher field values and increased the FWHM. The rate of core size decrease and aggregation were inversely proportional to the concentration of the incubated NPs, due to their slower biodegradation kinetics. The results of this model experiment show that the MPI performance of the NPs in the acidic environments of the intracellular organelles (i.e., lysosomes and endosomes) can be highly dependent on their rate of internalization, residence time, and degradation.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Arami et al. (2014) studied this question.

synapsesocial.com/papers/6a1f5a3d2865985bbe2abcf6https://doi.org/10.1063/1.4867756
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Size‐dependent ferrohydrodynamic relaxometry of magnetic particle imaging tracers in different environments2013 · 93 citations
  2. 2Monodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging2013 · 151 citations
  3. 3Tailoring the magnetic and pharmacokinetic properties of iron oxide magnetic particle imaging tracers2013 · 60 citations
  4. 4Surface modification and functionalization of semiconductor quantum dots through reactive coating of silanes in toluene2006 · 50 citations
  5. 5Measurements of particle size distribution parameters in ferrofluids1978 · 718 citations