Answers are grounded in this paper and cite their sources.
In molecular communications, the direct detection of signaling molecules may be challenging due to the lack of suitable sensors and interference from co-existing substances in the environment. Motivated by examples in nature, we investigate an indirect detection mechanism using chemical reactions between the signaling molecules and a molecular probe to produce an easy-to-measure product at the receiver. The underlying reaction-diffusion equations that describe the concentrations of the reactant and product molecules in the system are non-linear and coupled, and cannot be solved in closed-form. To analyze these molecule concentrations, we develop an efficient iterative algorithm by discretizing the time variable and solving for the space variables in each time step. We also derive insightful closed-form solutions for a special case. The accuracy of the proposed algorithm is verified by particle-based simulations. Our results show that the concentration of the product molecules has a similar characteristic over time as the concentration of the signaling molecules. We analyze the bit error rate (BER) for a threshold detector and highlight that significant improvements in the BER can be achieved by carefully choosing the molecular probe and optimizing the detection threshold.
No takes yet. Share an insight, caveat, or question.
Cao et al. (2020) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: