Stimuli were delivered to 12 subjects in a sequence that included regularly occurring standard tone pips, random warning tone pips, and random while noise bursts. Half the noise bursts were preceded by warning tones (high probability), and half were not (low probability). There were four runs, each having one of two noise burst intensities, and each having the warning tone and noise bursts either both task‐relevant to a reaction time task or both task irrelevant. Event‐related potentials (ERPs) were obtained by signal averaging in F 2 , C 2 , P 2 and eye leads. The P 3 to the warning tone was largest in P, and was not affected by task relevance. CNV s preceded all the high probability noise bursts. These CNV s had an amplitude of 5μV even when the bursts were task irrelevant. Low probability noise bursts elicited larger P3 s in all leads for the task‐irrelevant condition, but only in P z for the task‐relevant conditions. In C z , the amplitudes of NI. P 2 , and P 3 to the high probability. task‐relevant noise bursts correlated with the amplitude of the preceding CNV.
No takes yet. Share an insight, caveat, or question.
Roth et al. (1976) studied this question.