Key result
A transmission line model with a nonlinear load and Zener diode successfully simulated realistic aortic pressure and flow waveforms and aortic input impedance similar to a Windkessel model.
Answers are grounded in this paper and cite their sources.
A computational model using a transmission line with a nonlinear load and Zener diode successfully simulates realistic aortic pressure and flow waveforms.
The arterial tree is depicted as a single transmission line of tapered characteristic impedance with a nonlinear load. This load contains a Zener diode to simulate the 'Waterfall' behaviour caused by smooth muscle tension around the resistance vessels. A shunt resistor represents arterio-venous shunts. The waterfall reference pressure is related to the peripheral blood flow by a feedback coefficient with a time-constant. This combination provides realistic aortic pressure and flow waveforms and an aortic input impedance similar to a 'Windkessel' model. To demonstrate low-frequency responses, the amplitude of the input signal is modulated by a binary, pseudo-random noise waveform, synchronised to the pulse and 63 pulse periods long.
No takes yet. Share an insight, caveat, or question.
Köbler et al. (2002) studied this question. Arterial pulse propagation and reflection model was evaluated on Aortic pressure and flow waveforms and aortic input impedance. A transmission line model with a nonlinear load and Zener diode successfully simulated realistic aortic pressure and flow waveforms and aortic input impedance similar to a Windkessel model.