November 1, 1998IEEE Transactions on Power Electronics468 citations

Harmonic and reactive power compensation based on the generalized instantaneous reactive power theory for three-phase four-wire systems

View Full Paper
FPFang Zheng PengGOG.W. OttDAD.J. Adams

Key Points

Key points are not available for this paper at this time.

Abstract

This paper presents harmonic and reactive power compensation based on a generalized theory of instantaneous reactive power for three-phase power systems. This new theory gives a generalized definition of instantaneous reactive power, which is valid for sinusoidal or nonsinusoidal and balanced or unbalanced three-phase power systems with or without zero-sequence currents and/or voltages. The properties and physical meanings of the newly defined instantaneous reactive power are discussed in detail. A harmonic and reactive power compensator based on the new theory for a three-phase harmonic-distorted power system with zero-sequence components in the load current and/or source voltage is then used as an example to show harmonic and reactive power measurement and compensation using the new theory. Simulation and experimental results are presented.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Peng et al. (1998) studied this question.

synapsesocial.com/papers/6a200bccd5e8712fdf65bde7https://doi.org/10.1109/63.728344
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Generalized instantaneous reactive power theory for three-phase power systems1996 · 773 citations
  2. 2A new interpretation of the Akagi-Nabae power components for nonsinusoidal three-phase situations1992 · 268 citations
  3. 3A new definition of instantaneous active-reactive current and power based on instantaneous space vectors on polar coordinates in three-phase circuits1996 · 174 citations
  4. 4Orthogonal decomposition of the currents in a 3-phase nonlinear asymmetrical circuit with a nonsinusoidal voltage source1988 · 351 citations
  5. 5Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components1984 · 3,379 citations