Active cancellation of disturbing signals is a common method in electromagnetic compatibility (EMC) of power electronic systems. In this paper, a new method of suppressing periodic disturbances is extended and applied. In this method, the disturbing harmonics are suppressed by a synthesized cancellation signal that is synchronized with the converter's operation. Here, the cancellation signal is synthesized from a number of destructive sine waves. The appropriate amplitudes and phases are found via a convenient and robust adaptive approach. As a special feature of this method, many troublesome effects, like delays or complex frequency characteristics, can be compensated easily. Therefore, this method does not suffer from the same limitations as previous active techniques. Until now, the method has only been proven for a small number of harmonics. In this study, it is applied to a wide frequency range of 150 kHz to 30 MHz of a 48-/12-V dc/dc converter, e.g., for automotive applications. An optimization strategy is developed from a causal model of the system. A test setup is realized, and the sensor's and injector's performances are discussed regarding the automotive EMC standard CISPR 25. Measurement results for the artificial network and the antenna are presented. The additional power losses are estimated.