Key result
Interventional cardiac magnetic resonance imaging achieved the highest technology readiness level of 8 for diagnostic right heart catheterization and cavotricuspid isthmus ablation, while most other procedures remained at level 5.
Why the study?
Clinical implementation of interventional CMR remains limited by the availability of MRI-compatible equipment despite CMR advantages over X-ray fluoroscopy or ultrasound guidance.
Systematic Review (n=117)
Interventional CMR has potential for widespread application, but current clinical translation remains modest (TRL ~5), with right heart catheterization and cavotricuspid isthmus ablation being the most advanced (TRL 8).
Answers are grounded in this paper and cite their sources.
Restricts most interventional CMR procedures to investigational use; extends the roadmap for advancing technology readiness beyond TRL 5.
BACKGROUND: Cardiac magnetic resonance (CMR) provides excellent temporal and spatial resolution, tissue characterization, and flow measurements. This enables major advantages when guiding cardiac invasive procedures compared with X-ray fluoroscopy or ultrasound guidance. However, clinical implementation is limited due to limited availability of technological advancements in magnetic resonance imaging (MRI) compatible equipment. A systematic review of the available literature on past and present applications of interventional MR and its technology readiness level (TRL) was performed, also suggesting future applications. METHODS: A structured literature search was performed using PubMed. Search terms were focused on interventional CMR, cardiac catheterization, and other cardiac invasive procedures. All search results were screened for relevance by language, title, and abstract. TRL was adjusted for use in this article, level 1 being in a hypothetical stage and level 9 being widespread clinical translation. The papers were categorized by the type of procedure and the TRL was estimated. RESULTS: animal studies. Diagnostic right heart catheterization and cavotricuspid isthmus ablation had the highest TRL of 8, meaning proven feasibility and efficacy in a series of humans. CONCLUSION: This article shows that interventional CMR has a potential widespread application although clinical translation is at a modest level with TRL usually at 5. Future development should be directed toward availability of MR-compatible equipment and further improvement of the CMR techniques. This could lead to increased TRL of interventional CMR providing better treatment.
No takes yet. Share an insight, caveat, or question.
Rier et al. (2022) conducted a systematic review in Cardiac invasive procedures (n=117). Interventional cardiac magnetic resonance imaging was evaluated on Technology readiness level (TRL). Interventional cardiac magnetic resonance imaging achieved the highest technology readiness level of 8 for diagnostic right heart catheterization and cavotricuspid isthmus ablation, while most other procedures remained at level 5.
Synapse has enriched 10 related papers. Consider them for comparative context: