Adding the auxiliary switches to the conventional H-bridge inverter is an effective way to eliminate the leakage current for transformerless PV systems, such as H5, H6, etc. Inspired by the newly developed embedded-switch H6 topology, a novel embedded-switch inverter (ESI) is proposed in this paper for three-phase transformerless PV systems. First, the operation principle and characteristics of the proposed ESI are analyzed. Second, the common-mode model of the three-phase ESI is established, based on which the main factors that affect the leakage current are discussed. The finding reveals that the switching states with conventional modulation strategy result in high-frequency common-mode voltage, which is the source of leakage current. In order to solve the problem, a new modulation strategy is presented for ESI to eliminate the high-frequency leakage current. Finally, the time-domain simulation and the experimental tests are carried out. The results verify the effectiveness of the proposed solution.