This paper presents the fabrication and the test results of two-axis micromachined micro-mirror steel scanners developed for display and imaging applications. The novel fabrication method uses the conventional lithography and electrochemical metal etching techniques. A single photomask is used to define the whole structure, resulting in a simple and inexpensive fabrication process. Two different devices are designed, fabricated and characterized to test the proposed methods. Both of them employ the magnetostatic actuation to generate excitation force/torque. First device (Type-A) is a gimballed cantilever one, and it is capable of an optical scanning angle of 11.7 ◦ and 23.2 ◦ in slow- and fast-scan directions, consuming a power of 42 mW and 30.6 mW, respectively. This structure has a quality factor of 287 in the slow-scan direction and a quality factor of 195 in the fast-scan one. The second device (Type-B) is a gimballed torsional one, and it has an optical scanning angle of 76 ◦ and 5.9 ◦ in slow- and fast-scan directions, consuming 37 mW and 39 mW, respectively. This structure has a quality factor of 132 in the slow-scan and 530 in the fast-scan directions, respectively. The maximum total optical scanning angles obtained for the slow- and fast-scan axes are 105◦ (gimballed torsional device, Type-B) and 42 ◦ (gimballed cantilever device, Type-A). (Some figures in this article are in colour only in the electronic version) 1.
No takes yet. Share an insight, caveat, or question.
Gökdel et al. (2009) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: