PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
February 4, 2000The Journal of Physical Chemistry B159 citations

Oxidation of CO on a Pt−Fe Alloy Electrode Studied by Surface Enhanced Infrared Reflection−Absorption Spectroscopy

View Full Paper
MWMasahiro WatanabeYZYimin ZhuHUHiroyuki Uchida

Key Points

Key points are not available for this paper at this time.

Abstract

To clarify the CO-tolerant mechanism at Pt-based alloy anode catalysts, surface-enhanced infrared reflection−absorption spectroscopy with the attenuated total reflection technique (ATR-SEIRAS), coupled with CV measurement, was used to observe the oxidation process of adsorbed CO on a typical Pt−Fe (Pt−Fe = 0.27/0.73) alloy. The alloy electrode exhibits a lower saturated coverage of CO (θCO = 0.55) than that of pure Pt (θCO = 1.0). The dominating linear CO is observed around 2000 cm-1 when the equilibrium adlayer of CO covers the alloy electrode; however, linear and bridged CO and also COOH were found at the pure Pt electrode at the same CO coverage in the non-steady-state. On the basis of our previous results that a Pt skin is formed during the repetitive potential cycling due to the dissolution of Fe on the alloy surface and the skin exhibits less electronic density in the d band, it can be explained that the lowered linear CO coverage and almost no bridged CO are obtained as the result of the lowered back-donation of d electrons from the Pt skin to adsorbates on the alloy surface. The wavenumber shift of the linear CO stretching to a lower value at the alloy, which is not simply predicted by the lowering of the back-donation of the d electron, is ascribed to the weakening of the C−Pt bond. As a presumable effect of the electronic structure change at the Pt skin, the dissociation−oxidation of adsorbed water as well as a formation of adsorbed HOOH species are clearly observed beyond 0.6 V in the electrolyte solution without CO, which is different from that at the pure Pt electrode. Carbonate species can also be detected around 1300−1450 cm-1, which are possibly produced by the surface reaction of CO2 with water.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Watanabe et al. (2000) studied this question.

synapsesocial.com/papers/6a20808cdf4cd797f4f421e5https://doi.org/10.1021/jp993001q
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Oxidation of Carbon Monoxide at a Platinum Film Electrode Studied by Fourier Transform Infrared Spectroscopy with Attenuated Total Reflection Technique1999 · 105 citations
  2. 2Electrooxidation of CO and H2/CO Mixtures on a Well-Characterized Pt3Sn Electrode Surface1995 · 212 citations
  3. 3A photoelectron spectroscopic study of the adsorption of CO and CO2 on platinum1975 · 83 citations
  4. 4Combined scanning tunnelling microscopy and in situ Fourier transform infrared study of dioxygen reduction on gold1992 · 37 citations
  5. 5Carbon monoxide adsorption on a Pt80Fe20(111) single-crystal alloy1994 · 30 citations