Key result
An inferior vena cava filter did not prevent fatal pulmonary embolism in a fully anticoagulated 62-year-old woman, as the thrombus propagated across the filter.
Why the study?
Fatal pulmonary embolism still occurs after inferior vena cava filter insertion, and clinicians need awareness of alternative mechanisms such as thrombus propagation across the filter.
Case Report (n=1)
No
This case highlights a rare but fatal mechanism of pulmonary embolism occurring via thrombus propagation across an IVC filter in a fully anticoagulated patient.
IVC filter failure despite anticoagulation warrants clinical vigilance in high-risk patients; this Level 5 case leaves open questions on filter efficacy.
Inferior vena cava (IVC) filters have since been implanted in the 1970s. The aim of implantation is to prevent the occurrence of fatal pulmonary embolism (PE). However, fatal pulmonary embolisms have been occurring after filter insertion. The mechanism is that either a thrombus or an embolus was already located cranial to the site of deployment of the filter within the inferior vena cava. And so after the filter implantation significant embolism can still occur. We present the case of a 62-year-old woman who had an IVC filter but died two weeks later from pulmonary embolism, through an unusual mechanism. The patient had a fracture of the left tibia, had open reduction and internal fixation developed pulmonary embolism secondary to deep vein thrombosis of the left lower limb. Anticoagulation was started, an IVC filter was inserted and she was discharged home with a therapeutic INR. However, she passed away two weeks later from pulmonary embolism, through the unusual mechanism of thrombus propagation across the IVC filter. The clinical significance of this article is to draw clinicians’ attention to the existence of another mechanism of fatal pulmonary embolism after an IVC filter insertion. The thrombus can propagate across the IVC filter leading to fatal pulmonary embolism.
No takes yet. Share an insight, caveat, or question.
Offei-Larbi et al. (2022) conducted a case report in Pulmonary embolism (n=1). Inferior Vena Cava (IVC) filter was evaluated on Fatal pulmonary embolism. An inferior vena cava filter did not prevent fatal pulmonary embolism in a fully anticoagulated 62-year-old woman, as the thrombus propagated across the filter.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: