PURPOSE: Clinically significant copy-number variants (CNVs) occur in 1% to 2% of pregnancies and are difficult to detect via prenatal cell-free DNA (cfDNA) screening because of the low fraction of fetal-derived cfDNA in maternal plasma. Here, we use fetal fraction amplification (FFA) and improved computational algorithms to enhance the resolution and sensitivity of CNV detection. METHODS: We implemented and characterized the performance of a hidden Markov model that identifies fetal CNVs. This CNV caller was analytically validated on 117 FFA samples, including 57 fetal-CNV-containing samples, and applied retrospectively to a cohort of more than 300k patient samples. RESULTS: Our assay was concordant with orthogonal testing and detected fetal CNVs ≥5 Mb with estimated aggregate sensitivity and specificity of >95.1% and >99.7%, respectively. The resolution of CNV detection was fetal fraction dependent, but 97.2% of samples reached ≥5-Mb resolution. Overall, CNVs ≥5 Mb were found in 1 in 500 pregnancies. CONCLUSION: FFA improves the sensitivity and resolution of CNV detection in prenatal cfDNA screening, allowing accurate detection of fetal CNVs as small as 1 Mb. Using our approach, we found that clinically significant fetal CNVs were detected more frequently than the common trisomies 13 and 18 that are recommended as part of guideline-based screening.
No takes yet. Share an insight, caveat, or question.
Acevedo et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: