A VSC-MTDC (multi-terminal dc) system consists of voltage-source converters (VSCs) connected to a dc network at their dc terminals. The MTDC is most vulnerable to a dc fault which paralyses all the VSCs until the dc fault is cleared. As dc circuit breakers are expensive, this paper proposes a solution based on extinguishing the dc fault current by opening all the ac-circuit breakers (ac-CBs) which the VSCs are already equipped with on the ac-sides. However, it is necessary to identify which dc line is the faulted line (in case it is a permanent fault) so that it can be isolated by fast dc switches (which are much more economical than the dc circuit breakers), prior to restoring the MTDC system by re-closing all the ac-CBs. This paper presents the handshaking method, which locates and isolates the faulted dc line and restores the MTDC without telecommunication.
No takes yet. Share an insight, caveat, or question.
Tang et al. (2007) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: