Key result
Aerosolizing LNP-mRNAs with a vibrating mesh nebulizer substantially increases particle size and alters physicochemical properties.
Why the study?
Pulmonary delivery of LNP-mRNAs via vibrating mesh nebuliser for vaccination elicits mucosal airway immunity to prevent infection establishment, prompting investigation into its impact on physicochemical properties.
p-value: p=< 0.05
Aerosolisation of LNP-mRNAs via vibrating mesh nebulizer causes structural alterations and size enlargement due to shear-induced fusion, suggesting the need for shear-less devices or formulation optimizations for inhaled delivery.
Requires caution for nebulized LNP-mRNA; leaves open shear-less devices or optimizations in preclinical models.
The delivery of lipid nanoparticle (LNP)-mRNAs to the lungs attracts fast increasing interests for vaccination, as the mucosal immunity in the airway can prevent the establishment of an infection rather than only reduce the level of infection associated with systemic immunity triggered via intramuscular injection. The vibrating mesh nebuliser was well utilized to atomize inhalation solutions/suspensions for pulmonary delivery hence employed in this study for aerosolising LNP-mRNAs. In comparison with pre-aerosolised LNP-mRNAs, the post-aerosolised vectors demonstrated a significant increase (t-test, unpaired, p < 0.05) in particle size (215-363 nm vs. 116-130 nm), polydispersity index (PDI: > 0.33 vs. < 0.27), zeta potential (ZP: 11-14 mV vs. 2.6-7.7 mV), and encapsulation efficiency (EE: ∼99 % w/w vs. ∼91 % w/w), indicating a structural alteration upon high-frequency mesh vibration (HFMV). The particle sizes of LNP-mRNAs were further enlarged upon inertial impaction, and the size increments were dependent on the velocities of airflow for impaction and the N/P ratios. The aerosolised mists were fine, with >54 % w/w deposited in lower respiratory tract and >28.5 % w/w further delivered to alveolar regions. Further, a model was created to elucidate the variations of physicochemical properties for LNP-mRNAs upon HFMV and inertial impaction, and it disclosed that the fluidity and shear-induced fusion of LNPs were the fundamental reasons to cause these unfavourable changes particularly the size enlargement. These insights reveal that the effective development of inhaled LNP-mRNAs will rely on shear-less devices, formulation optimizations, inhalable dry powders, and their potential combinations.
No takes yet. Share an insight, caveat, or question.
Li et al. (2025) studied this question. Aerosolisation by vibrating mesh nebulizer vs. Pre-aerosolised LNP-mRNAs was evaluated on Physicochemical properties (particle size, PDI, ZP, EE) (p=< 0.05). Aerosolisation of LNP-mRNAs using a vibrating mesh nebulizer significantly increased particle size (215-363 nm vs. 116-130 nm; p<0.05) and altered other physicochemical properties.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: