Key result
An initial monophasic shock of 360 J for direct-current cardioversion of persistent atrial fibrillation achieved a significantly higher success rate than a 200 J shock (96.0% vs 75.4%, P=0.003).
Why the study?
Does a higher initial energy monophasic shock of 360 J improve cardioversion success compared to 200 J in patients with persistent atrial fibrillation?
RCT (n=107)
Does a higher initial energy monophasic shock of 360 J improve cardioversion success compared to 200 J in patients with persistent atrial fibrillation?
An initial 360 J monophasic shock for cardioversion of persistent AF is more effective and causes less skeletal muscle damage than a 200 J initial shock.
Supports initial 360 J monophasic shocks for persistent AF cardioversion; extends RCT evidence favoring higher-energy protocols.
BACKGROUND: Electrical direct-current cardioversion (DCCV) has become a routine therapy for atrial fibrillation (AF), although some uncertainty remains regarding the optimal energy settings. AIMS: This study examines whether the use of a higher initial energy monophasic shock of 360 joules (J) for external DCCV, in patients with persistent AF would prove more effective, yet as safe, as the use of a lower initial energy 200 J shock. METHODS: A cohort of 107 patients with persistent AF was prospectively randomized to an initial synchronized DCCV shock of 360 J versus 200 J (n = 50 vs 57), followed by a similar shock sequence thereafter of four further shocks of 360 J for the two groups. In all patients the levels of troponin I (cTnI) were measured precardioversion and 18-20 hours later, the following day. In a subgroup of 36 patients in each group, the levels of creatine kinase (CK) and aspartate transaminase (AST) were measured pre- and 18-20 hours postcardioversion. RESULTS: The success rate for DCCV was significantly higher in the 360 J group compared to the 200 J group (96.0% vs 75.4%, P = 0.003). The mean CK IU/L levels (1137.5.0 vs 2411.8, P = 0.014) and AST levels (39.83 vs 52.86, P = 0.010) were significantly lower in the 360 J group compared to the 200 J group. There was no statistical rise in cTnI (microg/L) in either group (P = 1.00). The average number of shocks delivered (1.84 vs 2.56, P = 0.006) was significantly less in the 360 J group than in the 200 J group, although total energy requirements for DCCV were similar for the two groups (662.4 J vs 762.4 J, P = 0.67). CONCLUSION: For patients with persistent AF the use of a higher initial-energy monophasic shock of 360 J achieves a significantly greater success rate, with less skeletal muscle damage (and no cardiac muscle damage) as compared with the traditional starting energy of a 200 J DC shock.
No takes yet. Share an insight, caveat, or question.
Boos et al. (2003) conducted an RCT in Persistent atrial fibrillation (n=107). Higher initial energy monophasic shock vs. Lower initial energy shock of 200 J was evaluated on Success rate for DCCV (p=0.003). An initial monophasic shock of 360 J for direct-current cardioversion of persistent atrial fibrillation achieved a significantly higher success rate than a 200 J shock (96.0% vs 75.4%, P=0.003).