Why the study?
Risk assessment for TAVI in aortic stenosis is still developing and mostly focused on periprocedural mortality, leaving late adverse outcomes poorly predicted.
Does a novel TAVI futility risk model accurately predict 1-year composite adverse outcomes in patients undergoing TAVI for severe aortic stenosis?
Cohort (n=2,160)
Yes
Does a novel TAVI futility risk model accurately predict 1-year composite adverse outcomes in patients undergoing TAVI for severe aortic stenosis?
Answers are grounded in this paper and cite their sources.
A newly developed TAVI futility risk model provides moderate predictive ability for 1-year adverse outcomes, outperforming traditional surgical and TAVI risk scores.
BACKGROUND: Transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) risk assessment is still developing and mostly concerned with mortality in the periprocedural period. We therefore sought to develop and then validate a score to predict 1-year adverse outcome. METHODS: Patients that underwent TAVI for severe AS in the Israeli registry. Patients with unsuccessful/suboptimal implantation were excluded. The cohort was split to derivation/validation cohorts by a ratio of 70:30. The outcome was defined as 1-year composite of mortality, stroke, and no improvement in NYHA class (vs. baseline). Logistic regression was used to fit the prediction model. RESULTS: Out of 2,440 patients meeting inclusion criteria, 276 were excluded, leaving 2,160 patients for both cohorts. At 1 year, 299 (14%) patients experienced the adverse ("futile") outcome. The derived prediction model included mean aortic valve (AV) gradient, previous pacemaker, previous oncological disease, need for diuretics, baseline NYHA class, hemoglobin and creatinine levels, and nonfemoral access site. The model's area under the curve (AUC) was 0.69 in the derivation and 0.70 in the validation cohort. Performance of other scores in the validation cohort were lower (0.60 for STS, 0.55 for Euroscore2, 0.56 for TVT score, and 0.53 for TAVI2-score, p = .03). Based on three risk tiers, patients had a low risk (20/306, 7% futility), a medium risk (50/304, 17%), and high risk (18/37, 49%) for futility. CONCLUSIONS: The TAVI futility risk model can be used to provide further insight regarding prediction measures and/or patients' outcomes outside of the periprocedural period (NCT02023060).
No takes yet. Share an insight, caveat, or question.
Zusman et al. (2020) conducted a cohort in Severe aortic stenosis (n=2,160). TAVI futility risk model vs. STS, Euroscore2, TVT score, and TAVI2-score was evaluated on 1-year composite of mortality, stroke, and no improvement in NYHA class (vs. baseline) (AUC 0.70, p=0.03).
Synapse has enriched 10 related papers. Consider them for comparative context: