OBJECTIVE: The aim of this study was to evaluate the distribution of generated stress around implants and adjacent bone tissue using different implant-retained overdenture designs through photoelastic analysis. METHODS: Over an edentulous human mandible, achieved from a human model, 2 or 4 microunit analog abutments were embedded (Master; Conexao Systems Prosthodontics, São Paulo, Brazil), settled in the interforaminal region. Three models of photoelastic resin (Araltec Chemicals Ltda, Hunstman, Guarulhos, São Paulo, Brazil), with 2 or 4 incorporated implants and microunit abutments, were obtained from molds using silicone for duplication. Inclusion, finishing, and polishing procedures were applied on the frameworks. This study was based on 3 different mechanisms of implant-retained mandibular overdentures: O'ring (GI), bar-clip (GII) (both with 2 implants), and their association (GIII) (with 4 implants). After the adaptation of each overdenture system on the photoelastic models, 100-N alternate occlusal loads were applied on back-side and front-side regions. The photoelastic analysis was made with the aid of a plain polariscope linked to a digital camera, Sony Cybershot α100, which allowed visualization of the fringes and registration of images on digital photographs. RESULTS: The results demonstrated higher tension concentrated over the GIII, with a flat distribution of stress to the posterior ridge and overload on the posterior implants. GI showed the smaller stress level, and GII, intermediate level; there was distribution of stress to the posterior ridge in these 2 groups. CONCLUSION: The use of bar attachment proved to be a better alternative, because it showed a moderate level of tension with a more uniform stress distribution and possessed higher retention than did the ball system.
No takes yet. Share an insight, caveat, or question.
Machado et al. (2011) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context:
More from Journal of Craniofacial Surgery