PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
January 1, 2001Electrophoresis140 citations

Fabrication and evaluation of a carbon-based dual-electrode detector for poly(dimethylsiloxane) electrophoresis chips

View Full Paper
AGAndrew J. GawronRMR. Scott MartinSLSusan M. Lunte

Key Points

Key points are not available for this paper at this time.

Abstract

The first carbon-based dual-electrode detector for microchip capillary electrophoresis (CE) is described. The poly(dimethylsiloxane) (PDMS)-based microchip CE devices were constructed by reversibly sealing a PDMS layer containing separation and injection channels to another PDMS layer containing carbon fiber working electrodes. End-channel amperometric detection was employed and the performance of the chip was evaluated using catechol. The response was found to be linear between 1 and 600 microM with an experimentally determined limit of detection (LOD) of 500 nM and a sensitivity of 30 pA/microM. Collection efficiencies for catechol ranged from 36.0 to 43.7% at field strengths of 260-615 V/cm. The selectivity that can be gained with these devices is demonstrated by the first CE-based dual-electrode detection of a Cu(II) peptide complex. These devices illustrate the potential for a rugged and easily constructed microchip CE system with an integrated carbon-based detector of similar scale.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Gawron et al. (2001) studied this question.

synapsesocial.com/papers/6a20f318fd936e2c9649e3d0https://doi.org/10.1002/1522-2683(200101)22:2<242::aid-elps242>3.0.co;2-w
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Dual-Electrode Electrochemical Detection for Poly(dimethylsiloxane)-Fabricated Capillary Electrophoresis Microchips2000 · 302 citations
  2. 2Effects of injector geometry and sample matrix on injection and sample loading in integrated capillary electrophoresis devices1999 · 118 citations
  3. 3Influence of tyrosine on the dual electrode electrochemical detection of copper(II)-peptide complexes1992 · 39 citations
  4. 4Adsorption and anodic oxidation of glycylglycine and some amino acids on a gold electrode1986 · 23 citations
  5. 5Characterization of Electrochemical Array Detection for Continuous Channel Electrophoretic Separations in Micrometer and Submicrometer Channels1997 · 92 citations