Key result
A 5-DoF robotically steerable catheter with direct torsional capability was successfully designed, modeled, and demonstrated for mitral clip implantation in a phantom heart model.
Why the study?
Although dexterity and manipulability are essential in transcatheter mitral procedures, existing systems lack direct torsional capability.
A novel 5-DoF robotically steerable catheter with direct torsional capability was designed and successfully demonstrated for mitral clip implantation in a phantom model.
Feasibility in phantom supports robotic catheter development for mitral clip; leaves open in vivo and clinical validation.
This paper presents the mechanism and design of a robotically steerable catheter system for percutaneous and minimally invasive treatment of mitral regurgitation. One of the main causes of mitral regurgitation is an impaired mitral valve topology, that results in severe heart-related diseases. Repair or replacement of the mitral valve through open-heart surgery such as traditional sternotomy has been conducted as a treatment. However, at least 50 % of patients with severe mitral regurgitation are not candidates for this surgery due to their age or comorbidities. Recently, minimally invasive or transcatheter approaches for mitral valve repair/replacement have been gaining attention to minimize the surgery's risk and several catheter mechanisms have been proposed in early phase clinical trials. Although dexterity and manipulability are essential functions in the transcatheter procedure, a direct torsional capability has not been implemented in the systems. We present a design of a 5-DoF robotically steerable catheter having two bending joints, two torsion joints having a direct torquing design, and a mitral implant delivery module to provide dexterous manipulation of the tip of the catheter. Designs and kinematic models of each joint module are presented and their performance is verified with experiments. Lastly, a mitral clip implanting procedure is demonstrated in a phantom heart model.
No takes yet. Share an insight, caveat, or question.
Nayar et al. (2021) studied Mitral regurgitation. 5-DoF robotically steerable catheter was evaluated on Kinematic model performance and mitral clip implanting procedure in a phantom heart model. A 5-DoF robotically steerable catheter with direct torsional capability was successfully designed, modeled, and demonstrated for mitral clip implantation in a phantom heart model.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: