Key result
A new minimally invasive indicator dilution technique using an ultrasound contrast agent bolus showed a 0.93 correlation coefficient with standard echographic bi-plane ejection fraction measurements.
Why the study?
Does a minimally invasive ultrasound contrast agent dilution technique accurately measure left ventricular ejection fraction compared to standard echographic bi-plane measurements?
Observational (n=20)
Does a minimally invasive ultrasound contrast agent dilution technique accurately measure left ventricular ejection fraction compared to standard echographic bi-plane measurements?
A novel minimally invasive ultrasound contrast agent dilution technique demonstrates high correlation (r=0.93) with standard bi-plane echocardiography for measuring left ventricular ejection fraction.
Does not support routine clinical adoption; leaves open prospective validation of ultrasound contrast dilution for LVEF.
Left ventricular ejection fraction is an important cardiac-efficiency measure. Standard estimations are based on geometric analysis and modeling; they require time and experienced cardiologists. Alternative methods make use of indicator dilutions, but they are invasive due to the need for catheterization. This study presents a new minimally invasive indicator dilution technique for ejection fraction quantification. It is based on a peripheral injection of an ultrasound contrast agent bolus. Left atrium and left ventricle acoustic intensities are recorded versus time by transthoracic echocardiography. The measured curves are corrected for attenuation distortion and processed by an adaptive Wiener deconvolution algorithm for the estimation of the left ventricle impulse response, which is interpolated by a monocompartment exponential model for the ejection fraction assessment. This technique measures forward ejection fraction, which excludes regurgitant volumes. The feasibility of the method was tested on a group of 20 patients with left ventricular ejection fractions going from 10% to 70%. The results are promising and show a 0.93 correlation coefficient with echographic bi-plane ejection fraction measurements. A more extensive validation as well as an investigation on the method applicability for valve insufficiency and right ventricular ejection fraction quantification will be an object of future study.
No takes yet. Share an insight, caveat, or question.
Mischi et al. (2005) conducted an observational in Patients requiring left ventricular ejection fraction measurement (n=20). Minimally invasive indicator dilution technique using ultrasound contrast agent bolus vs. Echographic bi-plane ejection fraction measurements was evaluated on Correlation with echographic bi-plane ejection fraction measurements (Correlation coefficient 0.93). A new minimally invasive indicator dilution technique using an ultrasound contrast agent bolus showed a 0.93 correlation coefficient with standard echographic bi-plane ejection fraction measurements.