Key result
Bicuspid aortic valve was not associated with more rapid progression of mean gradient compared to tricuspid aortic valve (1.5 vs 2.3 mmHg/year; p=0.5), but increased the hazard of valve replacement.
Why the study?
Although bicuspid aortic valve predisposes patients to aortic stenosis more frequently and at a younger age, its influence on the rate of aortic stenosis progression remains unclear.
Does bicuspid aortic valve phenotype accelerate the progression of mild or moderate aortic stenosis compared to tricuspid aortic valve?
Cohort (n=236)
Does bicuspid aortic valve phenotype accelerate the progression of mild or moderate aortic stenosis compared to tricuspid aortic valve?
Absolute Event Rate: 1.5% vs 2.3%
p-value: p=0.5
Bicuspid aortic valve does not significantly accelerate the hemodynamic progression of mild or moderate aortic stenosis compared to tricuspid aortic valve, suggesting echocardiographic surveillance intervals do not need to be altered based on valve phenotype.
May not warrant altered surveillance intervals for bicuspid aortic valve; leaves open drivers of earlier replacement.
BACKGROUND: Bicuspid aortic valve is the most common congenital heart defect and predisposes patients to developing aortic stenosis more frequently and at a younger age than the general population. However, the influence of bicuspid aortic valve on the rate of progression of aortic stenosis remains unclear. METHODS: In 236 patients (177 tricuspid aortic valve and 59 bicuspid aortic valve) matched by initial severity of mild or moderate aortic stenosis, we retrospectively analyzed baseline echocardiogram at diagnosis with latest available follow-up echocardiogram. Baseline comorbidities, annualized progression rate of hemodynamic parameters, and hazard of aortic valve replacement were compared between valve phenotypes. RESULTS: Median echocardiographic follow-up was 2.6 (interquartile range [IQR] 1.6-4.2) years. Patients with tricuspid aortic stenosis were significantly older with more frequent comorbid hypertension and congestive heart failure. Median annualized progression rate of mean gradient was 2.3 (IQR 0.6-5.0) mmHg/year versus 1.5 (IQR 0.5-4.1) mmHg/year (p = .5), and that of peak velocity was 0.14 (IQR 0-0.31) m/s/year versus 0.10 (IQR 0.04-0.26) m/s/year (p = .7) for tricuspid versus bicuspid aortic valve, respectively. On multivariate analyses, bicuspid aortic valve was not significantly associated with more rapid progression of aortic stenosis. In a stepwise Cox proportional hazards model adjusted for baseline mean gradient, bicuspid aortic valve was associated with increased hazard of aortic valve replacement (hazard ratio: 1.7, 95% confidence interval [1.0-3.0], p = .049). CONCLUSION: Bicuspid aortic valve may not significantly predispose patients to more rapid progression of mild or moderate aortic stenosis. Guidelines for echocardiographic surveillance of aortic stenosis need not be influenced by valve phenotype.
No takes yet. Share an insight, caveat, or question.
Shang et al. (2021) conducted a cohort in Aortic stenosis (n=236). Bicuspid aortic valve vs. Tricuspid aortic valve was evaluated on Annualized progression rate of mean gradient (mmHg/year) (p=0.5). Bicuspid aortic valve was not associated with more rapid progression of mean gradient compared to tricuspid aortic valve (1.5 vs 2.3 mmHg/year; p=0.5), but increased the hazard of valve replacement.