Key result
An amplified P-wave duration ≥ 150 ms independently predicted a higher risk of arrhythmia recurrence (HR 2.03) following cryoballoon pulmonary vein isolation in patients with non-paroxysmal AF.
Why the study?
Outcomes of catheter ablation for non-paroxysmal AF remain suboptimal, and non-invasive stratification based on atrial cardiomyopathy could identify the best responders to PVI.
Does amplified P-wave duration predict arrhythmia recurrence in patients with persistent and long-standing persistent atrial fibrillation undergoing cryoballoon pulmonary vein isolation?
Observational (n=295)
Yes
Does amplified P-wave duration predict arrhythmia recurrence in patients with persistent and long-standing persistent atrial fibrillation undergoing cryoballoon pulmonary vein isolation?
Answers are grounded in this paper and cite their sources.
Amplified P-wave duration ≥150 ms is an independent predictor of arrhythmia recurrence after cryoballoon pulmonary vein isolation, identifying patients with significant atrial cardiomyopathy who may benefit from additional ablation strategies.
Introduction Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI 95% 1.28–3.21; p = 0.002). Conclusion APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.
No takes yet. Share an insight, caveat, or question.
Creta et al. (2023) conducted an observational in Persistent and long-standing persistent atrial fibrillation (n=295). Amplified P-wave duration ≥ 150 ms vs. Amplified P-wave duration < 150 ms was evaluated on Arrhythmia recurrence (AF or atrial tachycardia lasting >30 s) after a 3-month blanking period (HR 2.03, 95% CI 1.28-3.21, p=0.002). An amplified P-wave duration ≥ 150 ms independently predicted a higher risk of arrhythmia recurrence (HR 2.03) following cryoballoon pulmonary vein isolation in patients with non-paroxysmal AF.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: