Key result
Evaluation of the Austin Flint murmur in aortic regurgitation showed early diastolic mitral valve closure rates (152 +/- 24 mm/sec) were not significantly different from normals (232 +/- 10 mm/sec).
Why the study?
What are the sound pressure correlates and genesis of the Austin Flint murmur in patients with aortic regurgitation?
Observational (n=22)
What are the sound pressure correlates and genesis of the Austin Flint murmur in patients with aortic regurgitation?
Questions mitral valve closure dynamics in Austin Flint murmur genesis; leaves open its sound pressure correlates in aortic regurgitation.
Mitral valve motion and pressure correlates of the Austin Flint murmur (AFM) were investigated in nine patients with aortic regurgitation using high fidelity catheter tip micromanometers and the mitral valve echocardiogram (MVE). External phonocardiography demonstrated a mid-diastolic murmur (MDM) in eight subjects and a presystolic murmur (PSM) in five. Maximum intensity of both AFM components was found in the left ventricular (LV) inflow tract; the murmur was not recordable in the left atrium (LA). In two patients, an apparent AFM was recorded in the intracardiac phonocardiogram when absent externally. Only one subject had a significant late diastolic "reversed" or LV to LA gradient; in this patient, presystolic mitral regurgitation was shown angiographically but no PSM was present and MVE revealed absence of atriogenic mitral valve re-opening. In two subjects, a PSM disappeared from the external phono when a "reversed" gradient occurred during the diastolic pause following a ventricular premature systole; this LV to LA gradient was associated with diastolic mitral regurgitation recordable in the left atrial phono. In two patients, LV inflow phono showed the MDM to begin 80-120 msec after the aortic second sound and during the D to E phase of the MVE. The rate of early diastolic mitral valve closure in patients (152 +/- 24 mm/sec) was not significantly different from 13 normals (232 +/- 10 mm/sec). With regard to the genesis of the AFM, the present study concludes: 1) diastolic mitral regurgitation plays no role, and 2) antegrade mitral valve flow is required but simultaneous retrograde aortic flow may also be necessary.
No takes yet. Share an insight, caveat, or question.
Reddy et al. (1976) conducted an observational in Aortic regurgitation (n=22). High fidelity catheter tip micromanometers and mitral valve echocardiogram vs. Normal subjects was evaluated on Mitral valve motion and pressure correlates of the Austin Flint murmur. Evaluation of the Austin Flint murmur in aortic regurgitation showed early diastolic mitral valve closure rates (152 +/- 24 mm/sec) were not significantly different from normals (232 +/- 10 mm/sec).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: