Key result
Nurse-led electronic warfarin nomogram achieves ~61% time in therapeutic range in hemodialysis AF.
Why the study?
Patients on hemodialysis prescribed warfarin typically have lower time in therapeutic range compared to the general population, which may lead to reduced benefit or increased risk of over anticoagulation.
Does a nursing-led electronic warfarin nomogram provide adequate time in therapeutic range in patients on hemodialysis with atrial fibrillation?
Cohort (n=43)
No
Does a nursing-led electronic warfarin nomogram provide adequate time in therapeutic range in patients on hemodialysis with atrial fibrillation?
A nursing-led electronic nomogram yields acceptable warfarin control (TTR >60%) for the majority of stable hemodialysis patients with atrial fibrillation.
Supports feasibility of nursing-led nomogram for warfarin in HD-AF; hypothesis-generating and should not yet change practice.
BACKGROUND: Patients treated with hemodialysis and prescribed warfarin typically have lower time in therapeutic range (TTR) compared to the general population. This may result in less benefit or increased risk of over anticoagulation in these patients. OBJECTIVE: To assess effectiveness of use of an electronic nomogram for the management of warfarin therapy in patients treated with hemodialysis. DESIGN: Retrospective chart review. SETTING: Adult patients treated with hemodialysis. PATIENTS: Patients on hemodialysis receiving warfarin for the management of atrial fibrillation (AF) with therapy managed by nursing led electronic nomogram. MEASUREMENTS: Time in therapeutic range (as fraction and Rosendaal). METHODS: Retrospective chart review over 1 year of international normalized ratio (INR) results was completed, and TTR was calculated. Comparison of patients with TTR greater than 60% to those less than 60% was completed using chi-square analysis. RESULTS: Of 43 patients with warfarin therapy managed by the nomogram, the mean TTR was 55.2% (calculated by fraction method) or 61.2% (calculated by Rosendaal method). More than half of the patients (63.5%) had moderate to good control, defined as TTR greater than 60%. Female sex, liver disease, or history of substance use and more medication holds were associated with lower TTR. LIMITATIONS: Small sample size and retrospective nature of review. CONCLUSIONS: The results of this review supports the use of an electronic, nursing-led nomogram for the maintenance management of warfarin therapy in stable patients treated with hemodialysis, as use results in TTR greater than 60% for more than half of patients.
No takes yet. Share an insight, caveat, or question.
Defoe et al. (2021) conducted a cohort in Atrial Fibrillation in patients on hemodialysis (n=43). Nursing-led electronic warfarin nomogram was evaluated on Mean Time in Therapeutic Range (TTR) by Rosendaal method. A nursing-led electronic warfarin nomogram for maintenance management in hemodialysis patients with atrial fibrillation resulted in a mean Time in Therapeutic Range of 61.2% by the Rosendaal method.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: