Answers are grounded in this paper and cite their sources.
Condition monitoring (CM) of modular multilevel converters (MMCs) submodule insulated gate bipolar transistors (IGBTs) is of significance to ensure reliable operation. The ON-state voltage of IGBT is a promising indicator to perform CM while its application in MMC is tricky due to high blocking voltage and numerous submodules. In this article, a novel sensor-reduction approach is presented to infer the ON-state voltages of MMC submodule IGBTs. Such an estimation method of the ON-state voltages is based ON Kirchhoff’s voltage law (KVL) applied to an MMC arm. This method focuses on a statistical analysis of capacitor voltages and arm voltages. The switching-state combinations are specifically selected for the purpose. A case study is conducted on a single-phase seven-level MMC test bench to verify the proposed ON-state voltage estimation method, which only shows an error of less than 3%. Furthermore, continuous ON-state voltage estimations are made with this MMC test bench under steady-state operations and carry out statistical analysis of the inferred ON-state voltage at various deterioration levels. Finally, a confusion matrix is proposed, whose maximum accuracy reaches 92.4% for the early-deterioration condition.
No takes yet. Share an insight, caveat, or question.
Zhan et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: