Key points are not available for this paper at this time.
PURPOSE: We evaluated improvement in the rate of prostate cancer detection when using an extensive biopsy protocol involving peripheral cores. MATERIALS AND METHODS: We prospectively evaluated 303 consecutive men who underwent transrectal ultrasound guided biopsy due to elevated prostate specific antigen (PSA) and/or abnormal digital rectal examination. Ten biopsies were performed, including at least 5 at the base and middle of each lobe. In addition to standard biopsy at a 45-degree angle, a more peripheral 30-degree angle biopsy was obtained. At the apex only 1 standard biopsy was done. However, when prostate volume was greater than 50 cm.3, an additional peripheral biopsy was obtained at the apex. RESULTS: The complication rate in this biopsy protocol was 1% (3 patients). Prostate cancer was detected in 118 of the 303 men (38. 9%). Overall this extensive protocol resulted in 6.6% improvement in the detection rate. Improvement was 6.5% in men with PSA 10 ng./ml. or less and 7% in those with PSA greater than 10 (not significant). CONCLUSIONS: Increasing the number of biopsy cores and improving prostate peripheral zone sampling resulted in a significant improvement in the detection of prostate cancer.
Ravery et al. (Tue,) studied this question.